EPD Hub data node (staging)
Data stock: Default root data stock

Process data set overview page

HERZ Ball valves 00.01.000

Full name
HERZ Ball valves
Location
SI
Reference year
2026
Valid until
2031
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Material / Construction / All Constructions
Synonyms
Use advice for data set
Data set use approval
General comment
Ball valves are used as closing, filling - draining fitting in industry and construction. Ball valves are used wherever the medium flow has to be reliably closed. Operating pressure varies according to the size and is given in the data sheet. Products:1 2110 XX, Ball valve with T or lever handle and backflow preventer, PN 16; 1 2190 XX, Ball valve with lever handle, DZR brass; 1 2201 01-06, Ball valve with lever-handle, PN 25; 1 2202 01-12, Flush ball valve without/with lever, PN 16 (for flush mounting); 1 2202 81-83, Ball valve with connection for temperature sensor, PN 25; 1 2202 21-26, Ball valve with lever handle (sheet steel galvanised), PN 25; 1 2205 13, Ball valve with T-handle, straight version, red, PN 25 (for manifold); 1 2205 23, Ball valve with T-handle, straight version, blue, PN 25 (for manifold); 1 2211 XX, Ball valve with T or lever handle (silumin), PN 25; 1 2216 XX, Ball valve with T or lever handle (silumin), PN 25; 1 2221 0X, Ball valve with freely rotating union nut and T-handle, PN 25; 1 2224 2X, Angled ball valve with freely rotating union nut and T-handle, PN 25; 1 2224 03-13, Ball valve with T-handle, angle version (for steel/stainless steel distributor), PN 25; 1 2228 01-14, Ball valve with T or lever handle (silumin), PN 25; 1 2268 03, Ball valve for pump connection with non-return valve, PN 16; 1 2269 03, Ball valve for pump connection,PN16; 1 2412 01, Three-Port Ball Valve, PN 40; 1 2442 XX, Ball valve with freely rotating union nut, PN 16; 2 2110 01-12, Ball valve with T or lever handle and backflow preventer, PN 16 (drinking water version) Common characteristics for most Herz ball valves (series 1 22xx, 1 21xx, 1 24xx, etc.): Body: Forged brass (often nickel-plated or DZR/dezincification-resistant) Ball: Full bore, Seals: PTFE (ball & spindle/stem) or with EPDM. Connections: Female thread ISO 228, some with union nut or male thread Temperature range: -30 °C to +150 °C (water ≥0.5 °C, max. 110 °C short-term, no steam) Medium: Water, chilled water, heating, non-aggressive media. The main differences between the individual valves in the group are the percentage of brass by weight (approximately 81% for DN8 to 93% for DN50) and minor differences in the amounts of plastic and PTFE seals. These differences result in differences in environmental impacts of ≤20% for most primary input streams (brass, plastic, PTFE). The valve with the highest impact for most indicators is the DN8 model; therefore, it was selected as the worst representative for the statement of results.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Accredited third party review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
HERZ d.o.o.
Technical purpose
Ball valves are used as closing, filling - draining fitting in industry and construction. Ball valves are used wherever the medium flow has to be reliably closed. Operating pressure varies according to the size and is given in the data sheet. Products:1 2110 XX, Ball valve with T or lever handle and backflow preventer, PN 16; 1 2190 XX, Ball valve with lever handle, DZR brass; 1 2201 01-06, Ball valve with lever-handle, PN 25; 1 2202 01-12, Flush ball valve without/with lever, PN 16 (for flush mounting); 1 2202 81-83, Ball valve with connection for temperature sensor, PN 25; 1 2202 21-26, Ball valve with lever handle (sheet steel galvanised), PN 25; 1 2205 13, Ball valve with T-handle, straight version, red, PN 25 (for manifold); 1 2205 23, Ball valve with T-handle, straight version, blue, PN 25 (for manifold); 1 2211 XX, Ball valve with T or lever handle (silumin), PN 25; 1 2216 XX, Ball valve with T or lever handle (silumin), PN 25; 1 2221 0X, Ball valve with freely rotating union nut and T-handle, PN 25; 1 2224 2X, Angled ball valve with freely rotating union nut and T-handle, PN 25; 1 2224 03-13, Ball valve with T-handle, angle version (for steel/stainless steel distributor), PN 25; 1 2228 01-14, Ball valve with T or lever handle (silumin), PN 25; 1 2268 03, Ball valve for pump connection with non-return valve, PN 16; 1 2269 03, Ball valve for pump connection,PN16; 1 2412 01, Three-Port Ball Valve, PN 40; 1 2442 XX, Ball valve with freely rotating union nut, PN 16; 2 2110 01-12, Ball valve with T or lever handle and backflow preventer, PN 16 (drinking water version) Common characteristics for most Herz ball valves (series 1 22xx, 1 21xx, 1 24xx, etc.): Body: Forged brass (often nickel-plated or DZR/dezincification-resistant) Ball: Full bore, Seals: PTFE (ball & spindle/stem) or with EPDM. Connections: Female thread ISO 228, some with union nut or male thread Temperature range: -30 °C to +150 °C (water ≥0.5 °C, max. 110 °C short-term, no steam) Medium: Water, chilled water, heating, non-aggressive media. The main differences between the individual valves in the group are the percentage of brass by weight (approximately 81% for DN8 to 93% for DN50) and minor differences in the amounts of plastic and PTFE seals. These differences result in differences in environmental impacts of ≤20% for most primary input streams (brass, plastic, PTFE). The valve with the highest impact for most indicators is the DN8 model; therefore, it was selected as the worst representative for the statement of results.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.01.000
Time stamp (last saved)
2026-08-18T15:04:03.375+02:00
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Not defined)
  • ISO 14025 (Overall compliance: Not defined)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.