General comment
Cartridge fire dampers FBC are devices for use in heating, ventilation and air-conditioning (HVAC) systems at fire boundaries to maintain fire compartmentation and protect escape routes in case of fire in the building. FBC satisfies integrity, insulation and smoke leakage criteria for the declared time of fire resistance. Tested and classified in accordance with EN 1366-2 and EN 13501-3 standards with 300 Pa under-pression. Typical applications are in HVAC systems within walls, floors, and ceilings forming fire compartments in residential, commercial, or industrial buildings. It is suitable for use in mechanical ventilation systems where certified fire protection performance is required. Compact and easy to install, the damper provides reliable fire safety performance. The FBC fire damper is classified in accordance with EN 13501-3, achieving a fire resistance classification of EI 120 ve ho [VH] (i↔o) S. The product complies with the requirements of EN 15650 for fire dampers designing and EN 1366-2 for fire damper testing. The reference service life (RSL) of the product is 25 years under normal operating conditions, assuming correct installation and regular maintenance in accordance with manufacturer instructions. The FBC product is made primarily of metal, such as galvanized steel and aluminum, as well as synthetic materials like plastic and rubber, and calcium silicate, which is widely used for fire protection. Further information and product specific GWP calculations see additional document which is presented for each product on https://www.mp3-italia.it/.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Accredited third party review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
MP3 srl
Technical purpose
Cartridge fire dampers FBC are devices for use in heating, ventilation and air-conditioning (HVAC) systems at fire boundaries to maintain fire compartmentation and protect escape routes in case of fire in the building. FBC satisfies integrity, insulation and smoke leakage criteria for the declared time of fire resistance. Tested and classified in accordance with EN 1366-2 and EN 13501-3 standards with 300 Pa under-pression. Typical applications are in HVAC systems within walls, floors, and ceilings forming fire compartments in residential, commercial, or industrial buildings. It is suitable for use in mechanical ventilation systems where certified fire protection performance is required. Compact and easy to install, the damper provides reliable fire safety performance. The FBC fire damper is classified in accordance with EN 13501-3, achieving a fire resistance classification of EI 120 ve ho [VH] (i↔o) S. The product complies with the requirements of EN 15650 for fire dampers designing and EN 1366-2 for fire damper testing. The reference service life (RSL) of the product is 25 years under normal operating conditions, assuming correct installation and regular maintenance in accordance with manufacturer instructions. The FBC product is made primarily of metal, such as galvanized steel and aluminum, as well as synthetic materials like plastic and rubber, and calcium silicate, which is widely used for fire protection. Further information and product specific GWP calculations see additional document which is presented for each product on https://www.mp3-italia.it/.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.02.000
Time stamp (last saved)
2026-08-12T10:09:59.120+02:00
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Not defined)
  • ISO 14025 (Overall compliance: Not defined)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.